MRC | Criteria | Characteristic |
---|
ABMK | OVERALL WIDTH | 9.000 INCHES NOMINAL |
AGAV | END ITEM IDENTIFICATION | PROCESSOR UNIT |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
APNX | INPUT VOLTAGE RATING | 230.0 AC POUNDS PER HOUR WET 2ND ALTERNATE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | 12.0 DC VOLTS NOMINAL 1ST POWER OUTPUT |
CBBL | FEATURES PROVIDED | OVER VOLTAGE PROTECTOR AND EMI FILTER |
CWGH | OUTPUT CURRENT RATING | 200.0 DC AMPERES NOMINAL 4TH POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | FRONT PANEL 1ST POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 5.0 DC VOLTS NOMINAL 4TH POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 10.0 DC AMPERES NOMINAL 1ST POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 10.0 DC AMPERES NOMINAL 2ND POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | FRONT PANEL 4TH POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 1 1ST POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 1 4TH POWER OUTPUT |
CWHT | INPUT CONNECTION QUANTITY | 1 1ST ALTERNATE OPERATING POWER RQMT |
FEAT | SPECIAL FEATURES | REFERANCE PROCESSOR UNIT T.O.31R2-2GSQ235,FIG 8-4 INDX 183 |
CWHF | OUTPUT CONNECTION QUANTITY | 1 2ND POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 2ND POWER OUTPUT |
CWHT | INPUT CONNECTION QUANTITY | 1 2ND ALTERNATE OPERATING POWER RQMT |
CWKG | VENTILATION DESIGN TYPE | CONVECTION |
ADZC | ENVIRONMENTAL PROTECTION | GENERAL PURPOSE |
ANPM | INPUT PHASE | SINGLE 1ST ALTERNATE OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 2ND ALTERNATE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 115.0 AC POUNDS PER HOUR WET 1ST ALTERNATE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | 12.0 DC VOLTS NOMINAL 2ND POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 5.0 DC VOLTS NOMINAL 3RD POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 1ST ALTERNATE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 2ND ALTERNATE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | 0.1/70.0 DEG CELSIUS |
CWHC | OUTPUT CONTROL LOCATION | FRONT PANEL 2ND POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | FRONT PANEL 3RD POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 1 3RD POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 1ST POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 4TH POWER OUTPUT |
CWHM | INPUT CURRENT RATING | 200.0 AC AMPERES NOMINAL 1ST ALTERNATE OPERATING POWER RQMT |
CWHQ | INPUT CONNECTION TYPE | TERMINAL STRIP 1ST ALTERNATE OPERATING POWER RQMT |
ABHP | OVERALL LENGTH | 14.880 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 5.000 INCHES NOMINAL |
CWGH | OUTPUT CURRENT RATING | 19.0 DC AMPERES NOMINAL 3RD POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 3RD POWER OUTPUT |
CWHM | INPUT CURRENT RATING | 300.0 AC AMPERES NOMINAL 2ND ALTERNATE OPERATING POWER RQMT |
CWHQ | INPUT CONNECTION TYPE | TERMINAL STRIP 2ND ALTERNATE OPERATING POWER RQMT |