Item Name | Cable Specificationial Purpose Electrical |
Federal Supply Group (FSG) | Electric Wire and Power and Distribution Equipment |
Federal Supply Class (FSC) | 6145 Wire and Cable Electrical |
National Item Identification Number (NIIN) | 01-407-1696 (014071696) |
NCB Code | USA (01) |
Manufacturer | South Bay Cable Corp |
MRC | Criteria | Characteristic |
---|---|---|
MATT | Material | PLASTIC POLYETHYLENE TEREPHTHALATE 4TH POSITION TAPE ALL GROUPS |
MATT | Material | PLASTIC POLYPROPYLENE 1ST POSITION PRIMARY INSULATION FOURTH CONDUCTOR |
MATT | Material | PLASTIC POLYURETHANE 6TH POSITION JACKET CABLE |
MATT | Material | COPPER 2ND POSITION SHIELD BRAID, METALLIC SECOND CONDUCTOR |
SFTT | Surface Treatment | TIN 2ND POSITION SHIELD BRAID, METALLIC SECOND CONDUCTOR |
SFTT | Surface Treatment | TIN 3RD POSITION SHIELD BRAID, METALLIC THIRD GROUP |
CXCW | Conductor Form | STRANDED SINGLE CONDUCTOR |
MATT | Material | COPPER 5TH POSITION SHIELD BRAID, METALLIC THIRD GROUP |
MATT | Material | PLASTIC POLYETHYLENE TEREPHTHALATE 3RD POSITION TAPE SECOND CONDUCTOR |
MATT | Material | PLASTIC POLYETHYLENE 1ST POSITION PRIMARY INSULATION FIRST CONDUCTOR |
MATT | Material | PLASTIC POLYPROPYLENE 1ST POSITION PRIMARY INSULATION SEVENTH CONDUCTOR |
MATT | Material | PLASTIC POLYPROPYLENE 1ST POSITION PRIMARY INSULATION EIGHTH CONDUCTOR |
MATT | Material | PLASTIC POLYPROPYLENE 1ST POSITION PRIMARY INSULATION SIXTH CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 7 7TH CONDUCTOR |
AMQN | Conductor Quantity | 9 |
HUES | Color | BROWN 1ST POSITION PRIMARY INSULATION FOURTH CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 19 6TH CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 7 8TH CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 19 5TH CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 7 2ND CONDUCTOR |
HUES | Color | GREEN 1ST POSITION PRIMARY INSULATION SIXTH CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 19 3RD CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 7 9TH CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 19 4TH CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 7 1ST CONDUCTOR |
HUES | Color | ORANGE 1ST POSITION PRIMARY INSULATION NINTH CONDUCTOR |
HUES | Color | BLACK 1ST POSITION PRIMARY INSULATION FIRST CONDUCTOR |
AAGR | Cross-Sectional Shape Style | ROUND |
CXDC | Round Conductor Size | 16 AWG 4TH CONDUCTOR |
CXDC | Round Conductor Size | 16 AWG 5TH CONDUCTOR |
CXDC | Round Conductor Size | 18 AWG 9TH CONDUCTOR |
HUES | Color | GREEN 1ST POSITION PRIMARY INSULATION EIGHTH CONDUCTOR |
CXDC | Round Conductor Size | 22 AWG 1ST CONDUCTOR |
CXDC | Round Conductor Size | 18 AWG 7TH CONDUCTOR |
MRC | Decoded Requirement | Clear Text Reply |
CXDG | Strand Awg Size Per Conductor | 26 9TH CONDUCTOR |
ABJH | Temp Rating | -28.0 DEG CELSIUS AND 65.0 DEG CELSIUS |
CXDG | Strand Awg Size Per Conductor | 29 5TH CONDUCTOR |
CXDG | Strand Awg Size Per Conductor | 26 7TH CONDUCTOR |
CXDG | Strand Awg Size Per Conductor | 29 3RD CONDUCTOR |
CXDC | Round Conductor Size | 16 AWG 3RD CONDUCTOR |
CXDC | Round Conductor Size | 16 AWG 6TH CONDUCTOR |
CXDG | Strand Awg Size Per Conductor | 30 1ST CONDUCTOR |
CXDG | Strand Awg Size Per Conductor | 29 6TH CONDUCTOR |
CXDC | Round Conductor Size | 18 AWG 8TH CONDUCTOR |
CXDT | Group Quantity | 4 |
MATT | Material | COPPER CORE CONDUCTOR ALL CONDUCTORS |
CXFG | Conductor Sequence Within Groups | FIRST CONDUCTOR FIRST GROUP AND SECOND CONDUCTOR FIRST GROUP |
CXFG | Conductor Sequence Within Groups | SEVENTH CONDUCTOR FOURTH GROUP AND EIGHTH CONDUCTOR FOURTH GROUP AND NINTH CONDUCTOR FOURTH GROUP |
CXDC | Round Conductor Size | 22 AWG 2ND CONDUCTOR |
CXDG | Strand Awg Size Per Conductor | 26 8TH CONDUCTOR |
MATT | Material | COPPER 2ND POSITION SHIELD BRAID, METALLIC FIRST CONDUCTOR |
HUES | Color | RED 1ST POSITION PRIMARY INSULATION THIRD CONDUCTOR |
CXDG | Strand Awg Size Per Conductor | 29 4TH CONDUCTOR |
SFTT | Surface Treatment | TIN 2ND POSITION SHIELD BRAID, METALLIC FIRST CONDUCTOR |
HUES | Color | WHITE 1ST POSITION PRIMARY INSULATION SECOND CONDUCTOR |
SFTT | Surface Treatment | TIN CORE CONDUCTOR ALL CONDUCTORS |
CXDG | Strand Awg Size Per Conductor | 30 2ND CONDUCTOR |
MATT | Material | PLASTIC POLYETHYLENE TEREPHTHALATE 3RD POSITION TAPE FIRST CONDUCTOR |
HUES | Color | YELLOW 1ST POSITION PRIMARY INSULATION FIFTH CONDUCTOR |
HUES | Color | YELLOW 1ST POSITION PRIMARY INSULATION SEVENTH CONDUCTOR |
MATT | Material | PLASTIC POLYETHYLENE 1ST POSITION PRIMARY INSULATION SECOND CONDUCTOR |
CXDQ | Conductor Arrangement And Quantity | 2 SINGLES AND 2 TWISTED PAIR AND 1 TRIPLES |
CXFG | Conductor Sequence Within Groups | FIFTH CONDUCTOR THIRD GROUP AND SIXTH CONDUCTOR THIRD GROUP |
CXFG | Conductor Sequence Within Groups | THIRD CONDUCTOR SECOND GROUP AND FOURTH CONDUCTOR SECOND GROUP |
MATT | Material | PLASTIC POLYPROPYLENE 1ST POSITION PRIMARY INSULATION NINTH CONDUCTOR |
MATT | Material | PLASTIC POLYPROPYLENE 1ST POSITION PRIMARY INSULATION FIFTH CONDUCTOR |
MATT | Material | PLASTIC POLYPROPYLENE 1ST POSITION PRIMARY INSULATION THIRD CONDUCTOR |
ADVL | Cross Section Outside Diameter | 0.665 INCHES NOMINAL |
Relevant Components for NSN - 6145-01-407-1696, 6145014071696 | ||||
6150-01-631-7193 (6150016317193) | 6135-01-141-4916 (6135011414916) | 6150-01-599-1862 (6150015991862) | 6110-01-394-7370 (6110013947370) | |
6105-00-308-9337 (6105003089337) | 6145-01-572-3595 (6145015723595) | 6145-01-186-0780 (6145011860780) | 6145-01-361-4174 (6145013614174) | |
6150-14-379-8237 (6150143798237) | 6150-01-468-3719 (6150014683719) | 6150-01-515-8387 (6150015158387) | 6150-01-644-3668 (6150016443668) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.