Thank you for your interest in Eaton Corporation part number 78-137-1, a Circuit Breaker product we carry that is featured with the NSN 5925-00-881-9766. This component is ready for purchase at any time, so you are encouraged to complete the Request for Quote (RFQ) form provided below if you would like to obtain pricing information for your consideration. All we ask is that you supply us with essential details like desired item quantities, target price, and when fulfillment is expected, as this will ensure our response caters to any distinct specifications.
Note : We Will Not Share Your Information To Any Third Parties.
At ASAP Semiconductor, our goal is to make the process of finding and securing precise components simple, which is why we present vital listing details with each offering here on Boundless Aerospace. For instance, part number 78-137-1 was manufactured by Eaton Corporation under the CAGECode 74193, and with the NSN 5925-00-881-9766, it belongs to FSC 5925 Circuit Breakers. More than that, all our inventory is delivered with any pertinent qualifying certifications or manufacturer trace documentation for your further benefit. Bearing all of this in mind, be sure to request a quote for part number 78-137-1 today, and we will be in touch as soon as possible.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-00-881-9766 Item PartTypeName: CIRCUIT BREAKER | 5925 | 008819766 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
78-137-1 | 2 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.437 INCHES NOMINAL |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.625 INCHES NOMINAL |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING W/PANEL SEAL |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 50.0 DC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO |
CQJX | NOMINAL THREAD SIZE | 0.375 INCHES |
THSD | THREAD SERIES DESIGNATOR | UNEF |
TTQY | TERMINAL TYPE AND QUANTITY | 8 WIRE HOOK |
AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
ABXD | BUSHING LENGTH | 0.310 INCHES NOMINAL |
ADAQ | BODY LENGTH | 1.531 INCHES NOMINAL |
ADAT | BODY WIDTH | 1.250 INCHES NOMINAL |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.797 INCHES NOMINAL |
AKPX | POLE QUANTITY | 2 |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 3.0 AMPERES DC SECOND LOCATION |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 5.0 AMPERES DC FIRST LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 500.0 DC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 120.0 ALL LOCATIONS |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | RELAY TRIP ALL LOCATIONS |