Thank you for your interest in Ortho Clinical Diagnostics Inc part number DT60 II W DTE AND DTSC, a Analyzer Clinical Chemistry product we carry that is featured with the NSN 6630-01-332-7886. This component is ready for purchase at any time, so you are encouraged to complete the Request for Quote (RFQ) form provided below if you would like to obtain pricing information for your consideration. All we ask is that you supply us with essential details like desired item quantities, target price, and when fulfillment is expected, as this will ensure our response caters to any distinct specifications.
Note : We Will Not Share Your Information To Any Third Parties.
At ASAP Semiconductor, our goal is to make the process of finding and securing precise components simple, which is why we present vital listing details with each offering here on Boundless Aerospace. For instance, part number DT60 II W DTE AND DTSC was manufactured by Ortho Clinical Diagnostics Inc under the CAGECode 03KD1, and with the NSN 6630-01-332-7886, it belongs to FSC 6630 Chemical Analysis Instruments. More than that, all our inventory is delivered with any pertinent qualifying certifications or manufacturer trace documentation for your further benefit. Bearing all of this in mind, be sure to request a quote for part number DT60 II W DTE AND DTSC today, and we will be in touch as soon as possible.
MRC | Criteria | Characteristic |
---|---|---|
DPTH | Depth | 14.000 INCHES |
CBBL | Features Provided | BATCH PROCESSING AND DATA ENTRY KEYBOARD AND DISCRETE PROCESSING AND INTEGRAL PRINTER AND RS232 PORT AND STAT PROCESSING |
ELEC | Voltage In Volts | 110.0 AND 240.0 |
MRC | Decoded Requirement | Clear Text Reply |
ACDC | Current Type | AC |
CYFV | Method Of Analysis | COLORIMETRIC AND KINETIC ENZYME/RATE TEST AND POTENTIOMETRIC/ION SELECTIVE ELECTRODE |
CYFZ | Test Sample/Specimen Size | 12.0 MICROLITERS |
CYGD | Throughput Per Hour | 50 SAMPLES/SPECIMENS MINIMUM |
ACZB | Frequency Rating | 50.0 HERTZ NOMINAL OR 60.0 HERTZ NOMINAL |
CYFW | Wavelength Range Data Non-Availability | NOT INCLUDED AS AN ESSENTIAL CHARACTERISTIC IN THE SPECIFICATION/CID COVERING THIS STANDARD NSN |
CYFY | Analysis Test/Measurement Range | ALBUMIN 3-5 G/DL; AMYLASE 5-900 U/L; CREATINE 0.1-15 MG/DL; GLUCOSE 20-450 MG/DL; UREA NITROGEN 1-100 MG/DL; PHOSPHORUS 0.5-13 MG/DL; TOTAL BILIRUBIN 0.1-20 MG/DL; TOTAL PROTEIN 2-11 G/DL; ASPARTATE AMINOTRANSFERASE (AST) 4-950 U/L; ALANINE AMINOTRANSFERASE (ALT) 3-950 U/L; CREATINEKINASE (CK) 20-1600 U/L; CALCIUM 3-15 MG/DL; SODIUM 95-215 MMO1/L; POTASSIUM 1-11 MMQ1/L; CHLORIDE 65-140 MMO1/L; CARBON DIOXIDE 5-50 MMO1/L |
CYGE | Test Sample/Specimen Delivery Device | PIPET, HANDHELD AUTOMATIC |
AKYD | Accessory Components And Quantity | PIPETTE(S) |
FEAT | Special Features | DRY CHEMICAL TECHNOLOGY; SOLID STATE |
AQXY | Test Type For Which Designed | ALBUMIN; AMYLASE; CREATININE; GLUCOSE; UREA NITROGEN; PHOSPHORUS; TOTAL BILIRUB; TOTAL PROTEIN; ASPARTATE AMINOTRANSFERASE,(AST); ALANINE AMINOTRANSFERASE,(ALT); CREATINE KINASE (CK); CALCIUM; SODIUM; POTASSIUM; CHLORIDE; CARBON DIOXIDE |
ABRN | Height | 7.000 INCHES |
WDTH | Width | 42.000 INCHES |
CYFX | Electrode Type | CALCIUM/CA++ AND CARBON DIOXIDE/CO2 AND CHLORIDE/CL- AND POTASSIUM/K+ AND SODIUM/NA+ |