Thank you for your interest in Schneider Electric Gmbh part number Q1350VH, a Circuit Breaker product we carry that is featured with the NSN 5925-01-050-9030. This component is ready for purchase at any time, so you are encouraged to complete the Request for Quote (RFQ) form provided below if you would like to obtain pricing information for your consideration. All we ask is that you supply us with essential details like desired item quantities, target price, and when fulfillment is expected, as this will ensure our response caters to any distinct specifications.
Note : We Will Not Share Your Information To Any Third Parties.
At ASAP Semiconductor, our goal is to make the process of finding and securing precise components simple, which is why we present vital listing details with each offering here on Boundless Aerospace. For instance, part number Q1350VH was manufactured by Schneider Electric Gmbh under the CAGECode 56365, and with the NSN 5925-01-050-9030, it belongs to FSC 5925 Circuit Breakers. More than that, all our inventory is delivered with any pertinent qualifying certifications or manufacturer trace documentation for your further benefit. Bearing all of this in mind, be sure to request a quote for part number Q1350VH today, and we will be in touch as soon as possible.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-050-9030 Item Description: Circuit Breaker | 5925 | 010509030 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Q1350vh | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
TTQY | Terminal Type And Quantity | 3 COMPRESSION |
CPLM | Maximum Continuous Load Current Rating Per Pole | 50.0 AMPERES AC ALL LOCATIONS |
AFJN | Fragility Factor | MODERATELY RUGGED |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 10000.0 AC ALL LOCATIONS |
FREQ | Frequency In Hertz | 60.0 ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRJ | Trip Release Method | THERMAL-MAGNETIC ALL LOCATIONS |
AJEC | Boss Height | 0.250 INCHES NOMINAL |
AKPX | Pole Quantity | 3 |
MRC | Decoded Requirement | Clear Text Reply |
AXHR | Mounting Facility Type And Quantity | 6 TERMINAL |
CPRQ | Reset Method | MANUAL |
CRCF | Trip Release Ambient Temp Rating | 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRW | Actuator Function | TRIP-RESET |
ADAT | Body Width | 2.230 INCHES NOMINAL |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
ADTV | Case Material | PLASTIC |
TTQY | Terminal Type And Quantity | 3 CLIP AND |
ADAQ | Body Length | 6.250 INCHES NOMINAL |
ADAU | Body Height | 2.580 INCHES NOMINAL |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.740 INCHES NOMINAL |
AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC ALL LOCATIONS |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 240.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
CPRX | Actuator Position Designation | AT POLE TWO |
CQXF | Inclosure Protection Type For Which Designed | FUNGUS RESISTANT |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.