Thank you for your interest in Unisys Corporation part number W12873, a Transformer Power product we carry that is featured with the NSN 5950-00-829-1224. This component is ready for purchase at any time, so you are encouraged to complete the Request for Quote (RFQ) form provided below if you would like to obtain pricing information for your consideration. All we ask is that you supply us with essential details like desired item quantities, target price, and when fulfillment is expected, as this will ensure our response caters to any distinct specifications.
Note : We Will Not Share Your Information To Any Third Parties.
At ASAP Semiconductor, our goal is to make the process of finding and securing precise components simple, which is why we present vital listing details with each offering here on Boundless Aerospace. For instance, part number W12873 was manufactured by Unisys Corporation under the CAGECode 65180, and with the NSN 5950-00-829-1224, it belongs to FSC 5950 Coils and Transformers. More than that, all our inventory is delivered with any pertinent qualifying certifications or manufacturer trace documentation for your further benefit. Bearing all of this in mind, be sure to request a quote for part number W12873 today, and we will be in touch as soon as possible.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-829-1224 Item PartTypeName: TRANSFORMER,POWER | 5950 | 008291224 | P | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | ||||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
951-0201-400 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-WYE |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.063 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.625 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 4.625 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 105.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 4.08 AMPERES AC MINIMUM SINGLE COMPONENT SINGLE SECONDARY AND 5.7 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
CRMJ | WINDING POWER RATING | 51.5 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 8.57 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY AND 9.04 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 9 STANDOFF,SOLDER LUG |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.281 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.313 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.843 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.875 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 89.5 VOLT-AMPERE SINGLE COMPONENT |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 440.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
TEST | TEST DATA DOCUMENT | 10001-2115813 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAW |